PROTEGO®
Pressure and Vacuum Relief Valves with Flame Arrester

Cutaway 3D render of a red industrial valve showing internal components inside the housing, with a gray side-mounted actuator on a black background.

Reliable tank protection with controlled venting and explosion protection

Pressure and Vacuum Relief Valves with integrated Flame Arrester Flammendurchschlagsicherung Device fitted to the opening of an enclosure, or to the connecting pipe work of a system of enclosures, and whose intended function is to allow flow but prevent the transmission of a flame. Unit combine two critical safety functions into a single unit: controlled tank breathing and protection against flame transmission. This configuration is widely used in storage tank systems handling flammable vapours, where both pressure and vacuum Unterdruck Vacuum is the pressure in an enclosed space that is lower than the ambient pressure. protection and ignition risk must be addressed in a compact, engineered solution.

Please select a product from our range below

Filter products
Device
Type
Place of Installation
Explosion Group
Pressure/Vacuum
Material
Size DN
Design
Heating Jacket
Horizontal / Vertical
Combustion Process
Connection Type

Válvula de alívio de pressão

BE/HR-D

Explosion Group

IIA1
D / IIA

Pressure Range:

2 up to 35 mbar

Pressure Relief Valve

D-SVL-EB-IIA

Explosion Group

IIA1
D / IIA

Pressure Range:

2 up to 60 mbar

Válvula de alívio de pressão de alta velocidade

DE-S-IIC

Explosion Group

B / IIC

Pressure Range:

60 up to 350 mbar

High Velocity Pressure Relief Valve

DE/S-IIB

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB

Pressure Range:

100 up to 500 mbar

Válvula de alívio de pressão de alta velocidade

DE/S-IIB3

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

100 up to 500 mbar

High Velocity Pressure Relief Valve

DE/S-MK VI - IIB3

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

60 up to 350 mbar

Válvula de alívio de pressão

P/EB

Explosion Group

IIA1
D / IIA

Pressure Range:

3.5 up to 210 mbar

Válvula de alívio de pressão

P/EB-E

Explosion Group

IIA1
D / IIA
C / IIB1

Pressure Range:

3.5 up to 210 mbar

Válvula de alívio de pressão

P/EBR

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

3.5 up to 210 mbar

Válvula de alívio de pressão

P/EBR-E-IIB1

Explosion Group

IIA1
D / IIA
C / IIB1

Pressure Range:

3.5 up to 210 mbar

Válvula de alívio de pressão

P/EBR-E-IIB3

Explosion Group

IIA1
D / IIA
C / IIB1

Pressure Range:

3.5 up to 210 mbar

Válvula de alívio de pressão e vácuo

PV/EB

Explosion Group

IIA1
D / IIA

Pressure Range:

2 up to 210 mbar

Vacuum Range:

-3.5 up to -35 mbar

Válvula de alívio de pressão e vácuo

PV/EB-E

Explosion Group

IIA1
D / IIA
C / IIB1

Pressure Range:

-3.5 up to -35 mbar

Vacuum Range:

2 up to 210 mbar

Válvula de alívio de pressão e vácuo

PV/EBR

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

-3.5 up to -50 mbar

Vacuum Range:

2 up to 210 mbar

Válvula de alívio de pressão e vácuo

PV/EBR-E-IIB1

Explosion Group

IIA1
D / IIA
C / IIB1

Pressure Range:

2 up to 210 mbar

Vacuum Range:

-3.5 up to -50 mbar

Válvula de alívio de pressão e vácuo

PV/EBR-E-IIB3

Explosion Group

IIA1
D / IIA
C / IIB3

Pressure Range:

-3.5 up to -50 mbar

Vacuum Range:

2 up to 210 mbar

Válvula de alívio de vácuo

SV/E

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Pressure Range:

-2 up to -60 mbar

Válvula de alívio de pressão de diafragma

UB/DF

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

3.5 up to 140 mbar

Válvula de alívio de pressão e vácuo de diafragma

UB/SF

Explosion Group

D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

-3.5 up to -35 mbar

Vacuum Range:

3.5 up to 140 mbar

Válvula de alívio de pressão e vácuo de diafragma

UB/SF-G

Explosion Group

D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

3.5 up to 140 mbar

Vacuum Range:

-3.5 up to -3.5 mbar

Pressure/Vacuum Diaphragm Valve

UB/SF-IIA1

Explosion Group

IIA1

Pressure Range:

3.5 up to 150 mbar

Vacuum Range:

-3.5 up to -35 mbar

Válvula de alívio de vácuo de diafragma

UB/VF

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

-3.5 up to -35 mbar

Válvula de alívio de vácuo

V/SV-AD-IIB3

Explosion Group

C / IIB3

Pressure Range:

-2 up to -35 mbar

Pressure/Vacuum Relief Valve

VD-SV-EB

Explosion Group

IIA1
D / IIA

Pressure Range:

2 up to 60 mbar

Vacuum Range:

-2 up to -60 mbar

Válvula de alívio de pressão e vácuo

VD/SV-AD, VD/SV-ADL

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

-3.5 up to 35 mbar

Vacuum Range:

-2 up to -35 mbar

Válvula de alívio de pressão e vácuo

VD/SV-HR

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

-2 up to -35 mbar

Vacuum Range:

3.5 up to 35 mbar

Válvula de alívio de pressão e vácuo

VD/SV-HRL

Explosion Group

IIA1
D / IIA

Pressure Range:

-2 up to -35 mbar

Vacuum Range:

3.5 up to 35 mbar

Válvula de alívio de pressão e vácuo

VD/TS

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Pressure Range:

-2 up to -25 mbar

Vacuum Range:

3.5 up to 50 mbar

Highlights of PROTEGO® Breather Valves

10% Technology
(set pressure close to relieving pressure)
Extreme tightness
reduced product losses
ZETOP
Zero Emission at Tank Operating Pressure
Lifecycle confidence
with maintenance-friendly designs and global service
Stable operation
during transients
Very high flow capacity
for your operations

Lorem Ipsum Zero Emissions with PROTEGO® Breather Valves

Lorem IpsumThe extreme tightness of PROTEGO® Valves guarantees Zero Emission at Tank Operating Pressure.

 

Due to the highly developed manufacturing technology of PROTEGO® valves the tank pressure Tankdruck Tank pressure is the pressure within a tank. is maintained up to set pressure Ansprechdruck Set pressure is the gauge pressure at the device inlet at which the relief device is set to start opening under service conditions. with a tightness that is far superior to the conventional standard. According to the PROTEGO® Standard PS-001 leak rates are measured at 90% of the set pressure. This testing ensures PROTEGO® Valves exceed the most stringent leakage rate requirements of EPA, API2000 and EN ISO 28300.

 

Lorem IpsumTo meet the goal of emission reduction, PROTEGO® full lift Hub Lift is the actual travel of the valve pallet from the main valve out of the closed position. vents utilize 10% overpressure Überdruck Overpressure refers to an increase in pressure in a system or vessel above the normal operating pressure. technology. This technology provides very short opening and closing pressure ranges. The vent only requires 10% overpressure above the set pressure to reach full performance. The tank pressure is maintained up to just below the maximum permissible tank pressure.
PROTEGO® 10% full-lift technology vents are a major benefit to emission reduction and to safe process plant operation.

The devices have performed as promised with low leak rates and minimal maintenance effort. We highly recommend them. 

Project Manager

PetroChina

Application Examples for PROTEGO® Breather Valves

Instalações de processamento químico e farmacêutico

Válvulas de respiro, corta-chamas, válvulas de alívio de emergência e válvulas pilotadas confiáveis para garantir a segurança em instalações químicas e farmacêuticas.
Explore more

Armazenamento em tanques

Válvulas de alívio de pressão e/ou vácuo, corta-chamas, válvulas de alívio de emergência e válvulas piloto-operadas para garantir a segurança e o desempenho na indústria de petróleo e gás.
Explore more

We provide engineered safety solutions.

Since 1954, PROTEGO® has built and provided Flame Arresters, Pressure and Vacuum Relief Valves and Tank Equipment, now with the help of more than 750 employees worldwide.

Engineering and Compliance

Correct valve selection is critical for safe and effective operation. Key selection criteria include:

Function
pressure relief, vacuum relief, or combined
Design type
connection orientation and configuration
Sealing type
metal or soft sealing depending on pressure
Operating conditions
temperature, pressure, volume flow, condensation, or polymerization risks

Valve sizing is based on required volume flow and maximum allowable pressure. Certified volume flow diagrams are available to support design.

Sizing must also account for:

Pressure losses in connected piping
Other installed devices
External backpressure effects

Key Features and Design Characteristics

The valve reaches full lift within 10% overpressure. This enables set pressure close to opening pressure, improving pressure control and reducing product Produkt Includes equipment, protective systems, devices, components and combinations of these. losses compared to conventional designs.

The sealing system maintains tightness above normal standards. This minimizes vapor loss and helps maintain system pressure up to the point of opening.

The valve opens later and re-seats earlier than conventional valves. This improves pressure stability and reduces loss of product or inert gas Inertgas Non-flammable gas which will not support combustion and does not react to produce a flammable gas. .

Large volume flows are achieved with only a small pressure difference. This supports efficient venting and can reduce the need for larger valve sizes.

The valves are suitable for use in explosion Explosion Abrupt oxidation or decomposition reaction producing an increase in temperature, pressure, or in both simultaneously. hazardous areas, supporting installation in regulated environments.

Operational Benefits

Reduced emissions
tightness far above the normal standard
Reduced product loss
later opening and earlier re-seating 
Flexibility for complex applications 
through custom design and certification
Lower maintenance impact 
due to modular, serviceable design

Get in Touch

Contact our engineers for your individual requirements.