PROTEGO®
Deflagration Flame Arresters, in-line

Close-up 3D render of a red flanged inline industrial device with a metallic central housing and multiple bolts, shown on a black background.

Please select an In-line Deflagration Flame Arrester from our range below

Filter products
Device
Type
Place of Installation
Explosion Group
Pressure/Vacuum
Material
Size DN
Design
Heating Jacket
Horizontal / Vertical
Combustion Process
Connection Type

Flame Arrester Unit

EV/VS, EV/VD

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Corta-chamas à prova de deflagração para tubulação

FA-CN-IIA, IIB3

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Corta-chamas à prova de deflagração para tubulação

FA-CN-IIA1

Explosion Group

IIA1

Corta-chamas à prova de deflagração para tubulação

FA-CN-IIC

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Corta-chamas à prova de deflagração para tubulação

FA-E

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Corta-chamas à prova de deflagração para tubulação

FA-E-IIA1

Explosion Group

IIA1

Corta-chamas à prova de deflagração para tubulação

FA-G

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

In-Line Deflagration Flame Arrester

FA-G-IIA1-P2.2

Explosion Group

IIA1

Corta-chamas à prova de deflagração para tubulação

FA-I

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Flame Arrester Unit

FA-I-FC

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Corta-chamas à prova de deflagração para tubulação

FA-I-PTFE

Explosion Group

IIA1
D / IIA

Flame Arrester

FA-I-V, FA-I-P

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Highlights of PROTEGO® Deflagration Flame Arresters

Nenhum incidente de flashback
quando dimensionado, instalado e mantido de acordo com a aplicação
Maior tempo de atividade e menores perdas
por meio de ventilação adequada do tanque e corta-chamas à prova de explosão
Confiança ao longo do ciclo de vida
com projetos de fácil manutenção e assistência técnica em todo o mundo
Conformidade simplificada
acompanhado de dados de testes documentados e manuais

Product Overview

Deflagration vs. Detonation

Flame Arrester Unit

Available Options

In-line devices
In-line devices installed directly in pipelines
OEM-integrated components

We are highly impressed to see the quality of the products and the knowledge to help us build a state-of-the-art storage terminal. We have always appreciated the timely deliveries of the flame arresters Flame Arresters A flame arrester, deflagration arrester, or flame trap is a device or form of construction that will allow free passage of a gas or gaseous mixture but will interrupt or prevent the passage of flame. and other equipment.  

Project Manager

Euro Tank Terminal

Typical Applications for PROTEGO® Deflagration Flame Arresters

  • Armazenamento refrigerado e criogênico

  • Armazenamento em tanques

  • Aterros sanitários e estações de tratamento de águas residuais

  • Instalações de processamento químico e farmacêutico

  • Tratamento com vapor

    We provide engineered safety solutions.

    Since 1954, PROTEGO® has built and provided Flame Arresters Apagallamas Device fitted to the opening of an enclosure, or to the connecting pipe work of a system of enclosures, and whose intended function is to allow flow but prevent the transmission of a flame. , Pressure and Vacuum Relief Valves and Tank Equipment, now with the help of more than 750 employees worldwide.

    When a flame front enters the arrester, it passes through the FLAMEFILTER® discs. The narrow gaps create a large heat transfer surface, removing energy from the flame faster than combustion can be sustained. The flame is extinguished within the element.

    How It Works

    Element Design

    The design of the element is not fixed. It is selected based on:

    Key Features and Design Characteristics

    Available in concentric, eccentric, and easy-access designs. Easy-access versions allow maintenance without disconnecting pipework- important in space-constrained or high-uptime environments.

    Element gap size is matched to the gas classification (MESG). Correct selection is critical to ensure effective flame arresting.

    Options are available depending on whether flow direction is fixed or variable.

    Designs are available for substances that may polymerise or crystallise, helping maintain long-term performance.

    Heating jackets or coils can be added where condensation or solidification is a risk.

    Where standard devices are not suitable, PROTEGO® can design and certify application-specific solutions.

    For in-line installations, it is important to understand that protection is time-limited. If an ignitable mixture continues to flow after a flame is stopped, a fire can develop on the arrester itself. For this reason, systems must include:

    • Temperature monitoring at the arrester
    • A defined response, such as nitrogen purging

    OEM-integrated Flame Arresters are tested and approved as part of the equipment assembly and are not used as standalone devices.

    Engineering and Compliance

    PROTEGO® Deflagration Flame Arresters are type-tested and certified according to ATEX and other international standards. Each device Bastidor A device is a pipe component that influences the media flow by opening, closing, or partially shutting off the flow channel or by dividing or mixing the media flow. is supplied with a statement of conformity defining its approved operating conditions.

    Additional installation considerations include:

    Sizing is based on the relationship between flow rate and pressure drop using the p/V performance diagram.

    Sizing is based on the relationship between flow rate and pressure drop using the p/V performance diagram.

    Operational Benefits

    Validated protection for OEM equipment
    tested as part of the full assembly
    Flexibility for complex applications 
    through custom design and certification
    Lower maintenance impact 
    due to modular, serviceable design
    Protection of equipment 
    by stopping flame propagation at the source