UB/VF

Válvula de alívio de vácuo de diafragmaà prova de defl gração

Features

Extreme Tightness
resulting in lowest possible product Product Includes equipment, protective systems, devices, components and combinations of these. losses and reduced environmental pollution
Flow Capacity
optimized flow capacity
Frost-Proof
optimal frost protection
Condensate Drainage
automatic condensate drain
Monitoring
monitoring of the load liquid by level indicator
Easy operation Monitoring
and maintenance by simply opening the hinged valve cap
Modular Design
allows replacement and cleaning of single FLAMEFILTER®
Suitable for challenging applications
particularly suitable for problematic products such as styrene, acrylates, etc.
Function and Description

highly developed vacuum relief valve

The PROTEGO® UB/VF diaphragm Diaphragm A diaphragm is a thin layer of material, which has a large surface area. valve is a worldwide unique vacuum relief valve Vacuum relief valve A vacuum relief valve is used to ventilate a part of the system and protects it from impermissible underpressure. combining the function of a dynamic and static flame arrester Static flame arrester Flame arrester designed to prevent flame transmission by quenching gaps. . It is primarily used as a device Device A device is a pipe component that influences the media flow by opening, closing, or partially shutting off the flow channel or by dividing or mixing the media flow. for flame transmission-proof Flame transmission-proof Characteristic of a device to avoid flashback. in-breathing on tanks, containers, and process equipment Equipment Machines, appliances, fixed or mobile devices, control parts and accessories, and warning and prevention systems, whether separate or combined, intended for the generation, transfer, storage, measurement, control, and conversion of energy, and for the processing of materials, which have their own potential source of ignition and may cause an explosion. . The valve offers reliable protection against vacuum Vacuum Vacuum is the pressure in an enclosed space that is lower than the ambient pressure. build up, prevents the in-breathing of air and product losses almost up to the set vacuum Set vacuum Internal negative gauge pressure at which a vacuum valve first opens. , and protects against atmospheric deflagration Deflagration Explosion propagating at subsonic velocity (EN 1127-1:1997). .

High Operational Reliability in Extreme Conditions

The PROTEGO® UB/VF diaphragm valve has proven itself over many years under a wide variety of operating conditions in the mineral oil and chemical industries. Worldwide, it is the only vent which works reliably with problem products such as styrene or acrylates. The set vacuum is adjusted with a freeze resistant water-glycol mixture which ensures safe operation under extreme cold weather conditions. The PROTEGO® UB/VF valve is available for substances from explosion Explosion Abrupt oxidation or decomposition reaction producing an increase in temperature, pressure, or in both simultaneously. group IIB3.

Composition

If a vacuum builds up in the tank, it is transmitted through pressure balancing tubes into the vacuum chambers (1), (2), which are connected to each other. This will remove the weight of the load liquid, and the atmospheric pressure will lift Lift Lift is the actual travel of the valve pallet from the main valve out of the closed position. the diaphragm (3) off the inner and outer valve seat Valve seat The valve seat is a component on which the valve pallet rests when the valve is closed. rings (4, 5), resulting in ventilation of the tank. The vacuum setting is adjusted via the filling level of the load liquid and can be checked by a floating level indicator (6).

advanced manufacturing technology

The tank vacuum is maintained up to the set vacuum with a tightness that is above the normal standards due to our highly developed manufacturing technology. This is achieved by the liquid loaded diaphragm pressing tightly around the special designed valve seat surface area even when the operating vacuum increases, which reduces surface pressure and unnecessary leakage. After the vacuum is balanced, the valve re-seats and provides a tight seal Seal A seal prevents or limits unwanted transfer of product from one container to another. Seal is used as superordinate term for all types of sealing elements. .

Main component - PROTEGO® flame arrester

At very low vacuum settings, the explosion pressures resulting from an atmospheric deflagration may be strong enough to lift the diaphragm off the valve seat rings. The ignition into the tank can be prevented by installing the PROTEGO® flame arrester unit PROTEGO® flame arrester unit The PROTEGO® flame arrester unit is the main component of a flame arrester. It prevents flame propagation. (7). This PROTEGO® flame arrester unit provides additional protection against atmospheric deflagration when the valve is open for maintenance and inspection. The valve can be used at an operating temperature Operating temperature Temperature reached when the equipment is operating under design conditions. of up to +60°C/ 140°F and meets the requirements of European tank design standard EN 14015 (Appendix L) and ISO 28300 (API 2000). EU conformity according to the currently valid ATEX directive. Approvals according to other national/international regulations on request.
Product Data and Features

Tabela de dimensões

Para escolher o diâmetro nominal (DN), veja os diagramas de vazão nas páginas seguintes

DN Vácuo 80 / 3" Vácuo 100 / 4"150 / 6"
a até -28 mbar615 até -22 mbar645680
a< -28 mbar765< -22 mbar795830
b410485590

Dimensões em mm

Dimensões de construção para a válvula de alívio de vácuo de diafragma com serpentina de aquecimento sob solicitação

Seleção do grupo de explosão

MESG Gr. expl. (IEC / CEN) Grupo gás (NEC)
≥ 0,65 mmIIB3C

Aprovações especiais sob solicitação

Tipo de conexão flangeada

EN 1092-1; Form B1
ASME B16.5 CL 150 R.F.

Outras conexões sob solicitação

Versão e especificação

O diafragma é calibrado por líquido.
Válvula de alívio de vácuo de diafragma na versão básicaUB/VF - –
Válvula de alívio de vácuo de diafragma com serpentina de aquecimento (temperatura máx. do meio de aquecimento +85°C)UB/VF - H

Além da versão padrão também é possível fornecer uma série de construções especiais especialmente desenvolvidas mediante consulta (p. ex. para tanque de acrilato ou de estireno etc.), que atendem de forma especial aos requisitos das condições de operação específicas nestes produtos.

Ajustes de pressão

Vácuo:-3.5 mbar-35 mbar
-1.4 inch W.C.-14 inch W.C.

Ajustes de vácuo maiores sob solicitação

Seleção do material do corpo

Execução CD
Corpo Ferro fundido Aço inoxidável
Parte superior da válvula Aço inoxidável Aço inoxidável
Serpentina de aquecimento (UB / VF-H-...) Aço inoxidável Aço inoxidável
Sedes de válvulas Aço inoxidável Aço inoxidável
VedaçãoFPMPTFE
DiafragmaA, BA, B
Conjunto abafador de chamasAC

Os corpos também podem ser fornecidos com revestimento de ECTFE

Materiais especiais sob solicitação

Seleção do material

Execução AB
DiafragmaFPMFEP

Materiais especiais sob solicitação

Combinações de material do conjunto abafador de chamas

Execução AC
Armação do FLAMEFILTER® Ferro fundido Aço inoxidável
FLAMEFILTER® Aço inoxidável Aço inoxidável
Espaçador Aço inoxidável Aço inoxidável

Materiais especiais sob solicitação

Diagrama de vazão

UB/VF DN100 Vacuum

UB/VF DN150 Vacuum

Este diagrama de vazão foi determinado em uma bancada de medição de vazão calibrada e certificada pela TÜV. A vazão V em m³/h se refere ao estado técnico padrão de ar, conforme ISO 6358 (20°C, 1bar). Para conversão em outras densidades e temperaturas, veja o cap. 1: Bases técnicas.

Applications