PROTEGO®
Pressure and Vacuum Relief Valves

Cutaway 3D render of a red industrial valve assembly showing internal chambers and a piston-like mechanism on a black background.

Reliable Tank Protection and Emission Reduction

During normal operation, storage tanks and process systems are exposed to pressure fluctuations caused by filling, emptying, thermal expansion, or operational changes. Without controlled venting, these fluctuations can lead to structural damage, product Produkt Includes equipment, protective systems, devices, components and combinations of these. loss, or safety risks. PROTEGO® Valves are available as pressure relief valves, vacuum relief valves, or as combined pressure/vacuum relief valves.

Please select a product from our range below

Produkte filtern
Gerät
Typ
Einbauort
Explosionsgruppe
Druck/Vakuum
Material
Size DN
Bauform
Heizmantel
Horizontal / Vertikal
Verbrennungsprozess
Anschlussart

Über- und Unterdruckrohrleitungsventil

DV/ZT

Überdruckbereich:

-2 bis -60 mbar

Unterdruckbereich:

2 bis 60 mbar

Über- und Unterdruckrohrleitungsventil

DV/ZT-F

Überdruckbereich:

60 bis 500 mbar

Unterdruckbereich:

-3.5 bis -50 mbar

Über- und Unterdruckrohrleitungsventil

DV/ZU

Überdruckbereich:

2 bis 60 mbar

Unterdruckbereich:

-3.5 bis -50 mbar

Über- und Unterdruckrohrleitungsventil

DV/ZU-F

Überdruckbereich:

60 bis 500 mbar

Unterdruckbereich:

-3.5 bis -50 mbar

Über- und Unterdruckrohrleitungsventil

DV/ZW

Überdruckbereich:

2 bis 60 mbar

Unterdruckbereich:

-3.5 bis -50 mbar

Über- und Unterdruckrohrleitungsventil

DV/ZW-F

Überdruckbereich:

60 bis 500 mbar

Unterdruckbereich:

-3.5 bis -50 mbar

Über- oder Unterdruckrohrleitungsventil

DZ/E

Überdruckbereich:

2 bis 60 mbar

Unterdruckbereich:

-2 bis -60 mbar

Über- oder Unterdruckrohrleitungsventil

DZ/E-F

Überdruckbereich:

60 bis 500 mbar

Unterdruckbereich:

-60 bis -500 mbar

Über- oder Unterdruckrohrleitungsventil

DZ/EA

Überdruckbereich:

5 bis 50 mbar

Unterdruckbereich:

-5 bis -50 mbar

Über- oder Unterdruckrohrleitungsventil

DZ/EA-F

Überdruckbereich:

-60 bis -500 mbar

Unterdruckbereich:

60 bis 500 mbar

Über- oder Unterdruckrohrleitungsventil

DZ/T

Überdruckbereich:

-2 bis -60 mbar

Unterdruckbereich:

2 bis 60 mbar

Über- oder Unterdruckrohrleitungsventil

DZ/T-F

Überdruckbereich:

60 bis 500 mbar

Unterdruckbereich:

-60 bis -500 mbar

Über- oder Unterdruckrohrleitungsventil

R/KSM

Überdruckbereich:

-5 bis -100 mbar

Unterdruckbereich:

5 bis 100 mbar

Druckreduzierventil, Rohrleitungsarmatur

ZM-R

Überdruckbereich:

bis -200 mbar

Unterdruckbereich:

bis 500 mbar

Highlights of PROTEGO® Breather Valves

10% Technology
(set pressure close to relieving pressure)
Extreme tightness
reduced product losses
ZETOP
Zero Emission at Tank Operating Pressure
Lifecycle confidence
with maintenance-friendly designs and global service
Stable operation
during transients
Very high flow capacity
for your operations

PROTEGO® 10% Technology and Tight Sealing

During normal operation, the valve pallet Ventilteller Valve pallet is the generic term for the assembly that rests on the valve seat. stays closed and seals the system. Pressure Relief Valves prevent vapor loss until shortly before the set pressure Ansprechdruck Set pressure is the gauge pressure at the device inlet at which the relief device is set to start opening under service conditions. is reached, while Vacuum Relief Valves prevent air from entering until the defined vacuum level is reached.

Once the set pressure is exceeded, the valve begins to open. PROTEGO® Valves reach full lift Hub Lift is the actual travel of the valve pallet from the main valve out of the closed position. within 10% overpressure Überdruck Overpressure refers to an increase in pressure in a system or vessel above the normal operating pressure. . This allows the valve to be set close to the allowable tank pressure Tankdruck Tank pressure is the pressure within a tank. while still releasing the required flow safely. This reduces unnecessary emissions compared to conventional valves that require significantly higher overpressure to fully open. 

The sealing between the valve pallet and the valve seat Ventilsitz The valve seat is a component on which the valve pallet rests when the valve is closed. is provided by an FEP air cushion seal Dichtung A seal prevents or limits unwanted transfer of product from one container to another. Seal is used as superordinate term for all types of sealing elements. , a metal to metal sealing, or a PTFE flat sealing, depending on the set pressure or on the application. The tightness of the PROTEGO® Valves is far above the normal standard (API 2000 or EN ISO 28300) and meets the stringent demands of emission control regulations.

PROTEGO® 10% Technology

The PROTEGO® valves demonstrated outstanding zero-emission performance and helped us achieve the environmental standards required for our site.

Senior Engineer

Application Examples for PROTEGO® Breather Valves

  • Kaltlagertanks

  • Anlagen für die chemische und pharmazeutische Verarbeitung

  • Erneuerbare Energien

  • Tanklager

  • Dampfbehandlung

    Key Features and Design Characteristics

    The valve reaches full lift within 10% overpressure. This enables set pressure close to opening pressure, improving pressure control and reducing product losses compared to conventional designs.

    The sealing system maintains tightness above normal standards. This minimizes vapor loss and helps maintain system pressure up to the point of opening.

    The valve opens later and re-seats earlier than conventional valves. This improves pressure stability and reduces loss of product or inert gas Inertgas Non-flammable gas which will not support combustion and does not react to produce a flammable gas. .

    Large volume flows are achieved with only a small pressure difference. This supports efficient venting and can reduce the need for larger valve sizes.

    The valve pallet is guided within the housing Gehäuse A housing is a solid shell, which surrounds a content, either protecting the content from external influences, or protecting the environment from the content. . This protects internal components from environmental exposure and supports consistent operation.

    The valves are suitable for use in explosion Explosion Abrupt oxidation or decomposition reaction producing an increase in temperature, pressure, or in both simultaneously. hazardous areas, supporting installation in regulated environments.

    Engineering and Compliance

    Correct valve selection is critical for safe and effective operation. Key selection criteria include:

    Function
    pressure relief, vacuum relief, or combined
    Design type
    connection orientation and configuration
    Sealing type
    metal or soft sealing depending on pressure
    Operating conditions
    temperature, pressure, volume flow, condensation, or polymerization risks

    Valve sizing is based on required volume flow and maximum allowable pressure. Certified volume flow diagrams are available to support design.

    Sizing must also account for:

    Pressure losses in connected piping
    Other installed devices
    External backpressure effects

    Operational Benefits

    Reduced emissions
    tightness far above the normal standard
    Reduced product loss
    later opening and earlier re-seating 
    Flexibility for complex applications 
    through custom design and certification
    Lower maintenance impact 
    due to modular, serviceable design

    Get in Touch

    Contact our engineers for your individual requirements.