FA-G-IIA1-P2.2

In-Line Deflagration Flame Arresterfor biogas, sewage gas and landfi ll gas, concentric design, bidirectional, endurance burning proof (under atmospheric conditions)

Features

Modular Design
allows replacement and cleaning of single FLAMEFILTER®
Fastest Disassembly and Assembly
of single FLAMEFILTER®
Pipe Thread Connection
Bi-Directional Flame Transmission
proof design
Provides Safety
Spare Parts
cost-effective flame arrester / spare parts
Function and Description

Protection of Fuel Supply Lines

The PROTEGO® FA-G-IIA1-P2.2 in-line deflagration flame arrester In-line deflagration flame arrester A deflagration flame arrester is designed to prevent the transmission of a deflagration. An in-line deflagration flame arrester is equipped with a pipe connection on both sides. was specially developed for bio-, sewage- and landfill-gas applications. The compact design of the PROTEGO® FA-G makes it the state of the art technology for installation in pipes with diameters of ½” up to 2”. The devices are installed with minimal distance to the burner to prevent flashback Flashback Phenomenon occurring in a flammable mixture of air and gas when the local velocity of the combustible mixture becomes less than the flame velocity, causing the flame to travel back to the point of mixture. in to the fuel feed lines. When installing the deflagration Deflagration Explosion propagating at subsonic velocity (EN 1127-1:1997). flame arrester, make sure that the distance between potential ignition sources and the location of the installed device Device A device is a pipe component that influences the media flow by opening, closing, or partially shutting off the flow channel or by dividing or mixing the media flow. , does not exceed the L/D ratio (pipe length/pipe diameter), for which the device was approved. As per EN ISO 16852 the L/D ratio is limited to (L/D) max ≤ 50 for deflagration flame arresters Deflagration flame arrester Flame arrester designed to prevent the transmission of a deflagration. It can be an end-of-line flame arrester or an in-line flame arrester. of explosion group IIA1.

For Explosion group IIA1 - Methan

The in-line deflagration flame arrester is symmetrical and offers bidirectional flame transmission protection. The device consists of two housing Housing A housing is a solid shell, which surrounds a content, either protecting the content from external influences, or protecting the environment from the content. parts (1) and two FLAMEFILTER® (2) in the center. The PROTEGO® FA-G-IIA1-P2.2 flame arrester protects against deflagrations and endurance burning Endurance burning Stabilized burning for an unlimited time. (under atmospheric condition Atmospheric conditions Atmospheric conditions are pressures from 80 kPa till 110 kPa and temperatures from -20°C up to +60°C. ) and short time burning Short time burning Stabilized burning for a specific time. for 1 min. for the maximum operating conditions of explosion group IIA1 - methane.

Many Individual Certifications

PROTEGO® FA-G devices for substances of explosion groups IIA, IIB3 and IIC (NEC groups D, C, and B) are shown on separate pages. The standard design can be used up to an operating temperature Operating temperature Temperature reached when the equipment is operating under design conditions. of +60°C / 140°F and an absolute operating pressure Operating pressure Operating pressure is the pressure existing at normal operating conditions within the system being protected. up to 2.2 bar / 31.9 psi. EU conformity according to the currently valid ATEX directive. Approvals according to other national/international regulations on request.

Tabela de dimensões

Para escolher o diâmetro nominal (DN), veja os diagramas de vazão nas páginas seguintes

DN G ½ G ¾ G 1 G 1 ¼ G 1 ½ G 2
a 80 80 100 100 155 155
b 55 55 76 76 124 124
c 10 100 110 110 170 170
d -— 400 400
SW 32 32 50 50 75 75

Dimensions in mm / inches, SW= width across flats

Seleção do grupo de explosão

MESG Gr. expl. (IEC / CEN)
≥ 1,14 mmIIA1

Aprovações especiais sob solicitação

Seleção da pressão máx. de trabalho

Expl. GrDNG ½G ¾G 1G 1 ¼G 1 ½G 2
IIA1 Pmax 2,2 2,2 2,2 2,2 2,2 2,2

Pmáx. = pressão de trabalho máxima admissível em bar absoluta, pressão de trabalho mais elevada sob solicitação

Indicação da temperatura máx. de trabalho

≤ 60°C / 140°F Ttemperatura máxima de trabalho admissível em °C
-Designation

temperaturas de trabalho mais elevadas, sob solicitação

Tipo de conexão

Rosca para tubo DIN ISO 228-1 DIN

outras conexões roscadas sob solicitação

Versão e especificação

Estão disponíveis três versões:
Corta-chamas à prova de deflagração para tubulação FA-G em versão básica, G ½" até 2"FA-G - –
Corta-chamas à prova de deflagração para tubulação com sensor de temperatura* integrado como proteção adicional contra combustão de curta duração de um lado, G 1½" até 2".FA-G - T
Corta-chamas à prova de deflagração para tubulação com dois sensores de temperatura* integrados como proteção adicional contra combustão de curta duração de ambos os lados, G 1½" até 2".FA-G - TB

*Termoresistência para grupo de equipamentos II, categoria (1) 2 (cat. GII (1) 2)

Seleção do material

ExecuçãoBC
CorpoAço inoxidávelHastelloy
VedaçãoPTFEPTFE
FLAMEFILTER®*Aço inoxidávelHastelloy

* os FLAMEFILTER® também podem ser fornecidos em tântalo, Inconel, cobre etc., em caso de utilização dos materiais do corpo listados.

Materiais especiais sob solicitação.

Diagrama de vazão

Este diagrama de vazão foi determinado em uma bancada de medição de vazão calibrada e certificada pela TÜV. A vazão V em m³/h se refere ao estado técnico padrão de ar, conforme ISO 6358 (20°C, 1bar). Para conversão em outras densidades e temperaturas, veja o cap. 1: Bases técnicas.

Applications