ER-V-LP

Emergency pressure relief valve

Function and Description

Patented Valve Pallet Technology

The valve will start to open as soon as the set pressure is reached and only requires a 10% pressure increase or opening pressure differential until full lift. Continuous investments in and a commitment to research and development have enabled PROTEGO® to develop a new valve pallet technology for which a patent has been granted. This patented valve pallet technology enables the typical safety valve Safety valve Valve which automatically, without the assistance of any energy other than that of the fluid concerned, discharges a quantity of the fluid so as to prevent a predetermined safe pressure being exceeded, and which is designed to re-close and prevent further flow of fluid after normal pressure conditions of service have been restored. characteristics to be applied to low pressure ranges while also maintaining a low leakage rate. Adopting this new patented valve pallet technology permits the valve to be set to just 10% below the maximum allowable working pressure of the tank and still vent the required flow.

Advanced Manufacturing Technology

Due to the sophisticated manufacturing technology, the tank pressure Tank pressure Tank pressure is the pressure within a tank. is maintained up to the set pressure, with a tightness that is far above the common standards. Once the excess pressure is released, the valve re-seats and seals tight again.
Product Data and Features

Tabela de dimensões

Para escolher o diâmetro nominal (DN), veja o diagrama de vazão da página seguinte

DN200 / 8"250 / 10"300 / 12"350 / 14"400 / 16"450 / 18"500 / 20"600 / 24"700 / 28"
a343406483533597635699813837
b378399409440455464481556571

Dimensões em mm

Seleção do material

Execução AB
Corpo Aço Aço inoxidável
Sedes de válvulas Aço inoxidável Aço inoxidável
Obturador da válvula Aço inoxidável Aço inoxidável
Vedação Aço inoxidável Aço inoxidável

Materiais especiais sob solicitação

Tipo de conexão flangeada

EN 1092-1; Form B1
ASME B16.5 CL 150 R.F.

Outras conexões sob solicitação

Versão e especificação

O obturador da válvula é calibrado por peso. Pressões de ajuste mais altas são realizadas geralmente com alavanca (veja ER/VH, ER/V) ou com válvula calibrada por mola (veja ER/V-F).
Pressure valve in basic designER-V-LP

Outros dispositivos especiais sob solicitação

Settings

DN 200 to DN 300+3.4 mbar+40 mbar
+1.4 inch W.C.+16 inch W.C.
DN 350 to DN 700+3.4 mbar+25 mbar
+1.4 inch W.C.+10 inch W.C.

Ajustes de pressões mais altos, veja tipo ER/V, ER/VH e ER/V-F.

Diagrama de vazão

Este diagrama de vazão foi determinado em uma bancada de medição de vazão calibrada e certificada pela TÜV. A vazão V em m³/h se refere ao estado técnico padrão de ar, conforme ISO 6358 (20°C, 1bar). Para conversão em outras densidades e temperaturas, veja o cap. 1: Bases técnicas.

Applications