Features
10% Technology
Extreme Tightness
Optimum Pressure Maintenance
High Flow Capacity
Used in Explosion Hazardous Areas
Sturdy Housing Design
Spring Loading (Overpressure Side)

Pressure or Backflow Protection in Venting or Exhaust Lines

Full Lift Technology

Optimal Performance
Dimensiones
To select the nominal size Diámetro nominal The nominal size is an alphanumeric designation of size for components in a piping system, used for reference purposes, comprising the letters DN followed by a dimensionless integer that is indirectly related to the physical size of the bore or outside diameter of the connections, expessed in millimeters. (DN), please use the flow capacity charts on the following pages
| DN | 40 / 1½“ | 50 / 2" | 80 / 3" | 100 / 4" | 150 / 6" | 200 / 8" | 250 / 10" |
| a | 280 / 11.02 | 280 / 11.02 | 340 / 13.39 | 390 / 15.35 | 520 / 20.47 | 650 / 25.59 | 750 / 29.53 |
| b | 210 / 8.27 | 210 / 8.27 | 280 / 11.02 | 310 / 12.20 | 390 / 15.35 | 565 / 22.24 | 610 / 24.02 |
| c | 605 / 23.82 | 605 / 23.82 | 730 / 28.74 | 870 / 34.25 | 1170 / 46.06 | 1030 / 40.55 | 1335 / 52.56 |
Dimensiones en mm / pulgadas
Larger sizes upon request
Dimensions for pressure and vacuum relief valve with heating jacket upon request
Selección de materiales para la vivienda
| Design | A | B |
| Housing | Steel | Stainless Steel |
| Heating jacket (DV / ZT-F-H-...) | Steel | Stainless Steel |
| Valve seat | Stainless Steel | Stainless Steel |
| Gasket | PTFE | PTFE |
Option: Housing with ECTFE- lining Lining Protective plastic lining with a defined minimum/maximum thickness to protect against aggressive mixtures (e.g., acid).
Special materials upon request
Selección de materiales para la válvula de presión
| Design | A |
| Pressure range [mbar] [inch W.C.] | >+60 up to +500 >+24 up to +200 |
| Valve pallet | Stainless Steel |
| Sealing | Metal to Metal |
| Spring | Stainless Steel |
Special materials upon request
For lower set pressure use type DV/ZT. Higher set pressure and lower set vacuum Set vacuum Internal negative gauge pressure at which a vacuum valve first opens. upon request.
Selección de materiales para la válvula de vacío
| Design | A* | B* | C | D |
| Pressure range [mbar] [inch W.C.] | -3,5 up to -5,0 -1.4 up to -2.0 | <-5,0 up to -14 <-2.0up to -5.6 | <-14up to -35 <-5.6up to -14 | <-35 up to -50 <-14up to -20 |
| Valve pallet | Aluminium | Stainless Steel | Stainless Steel | Stainless Steel |
| Sealing | FEP | FEP | Metal to Metal | Metal to Metal |
*by set pressure up to +150 mbar / +60 Inch W.C.
Special materials and lower set vacuumupon request.
Tipo de bridas de conexión
| EN 1092-1; Form B1 |
| ASME B16.5 CL 150 R.F. |
other types upon request
Diagrama de flujo volumétrico


Los diagramas de flujo volumétrico han sido determinados con un banco de pruebas de caudal calibrado y certifi - cado por TÜV. El flujo volumétrico V. en [m³/h] y el CFH se refi eren a las condiciones estándar de referencia de aire según ISO 6358 (20°C, 1bar). La conversión a otras densidades y temperaturas están referidas en el Vol. 1: “Fundamentos Técnicos”.


Detail X

Detail X

Detail Y

Tank connection
Si tienes alguna pregunta, comentario o sugerencia, nuestro equipo de expertos estará encantado de ayudarte.