VD/SV-HRL

Pressure/Vacuum Relief Valvedeflagration- and endurance burning-proof

Features

Extreme Tightness
resulting in lowest possible product Product Includes equipment, protective systems, devices, components and combinations of these. losses and reduced environmental pollution
More Efficient Opening and Closing
valve opens later and closes earlier than conventional valves
Safety Against Endurance Burning
Protection against Atmospheric Deflagration and Endurance Burning
Modular Design
allows replacement and cleaning of single FLAMEFILTER®
Function and Description

combined pressure and vacuum relief valve

The atmospheric deflagration Deflagration Explosion propagating at subsonic velocity (EN 1127-1:1997). and endurance burning Endurance burning Stabilized burning for an unlimited time. -proof VD/SV-HRL type PROTEGO® valve is a highly developed combined pressure/vacuum relief valve Pressure/vacuum relief valve Pressure/vacuum relief valve is an umbrella term that includes pressure or vacuum relief valve as well as pressure and vacuum relief valve. for high flow capacities with an integrated flame arrester. It is primarily used as a device Device A device is a pipe component that influences the media flow by opening, closing, or partially shutting off the flow channel or by dividing or mixing the media flow. for flame transmission proof in-breathing and out-breathing on tanks, containers, and process equipment Equipment Machines, appliances, fixed or mobile devices, control parts and accessories, and warning and prevention systems, whether separate or combined, intended for the generation, transfer, storage, measurement, control, and conversion of energy, and for the processing of materials, which have their own potential source of ignition and may cause an explosion. . The valve offers reliable protection against overpressure Overpressure Overpressure refers to an increase in pressure in a system or vessel above the normal operating pressure. and vacuum Vacuum Vacuum is the pressure in an enclosed space that is lower than the ambient pressure. , prevents the in-breathing of air and product losses almost up to the set pressure, and protects against atmospheric eflagration and endurance burning if stabilized burning Stabilized burning Steady burning of a flame stabilized at, or close to the flame arrester element. occurs.

10%-Technology

The PROTEGO® flame arrester unit is designed to achieve minimum pressure drop with maximum safety. The PROTEGO® VD/SV-HRL device is available for substances of explosion Explosion Abrupt oxidation or decomposition reaction producing an increase in temperature, pressure, or in both simultaneously. group IIA (NEC group D MESG > 0.9 mm). When the set pressure is reached, the valve starts to open and reaches full lift within 10% overpressure. This unique 10% technology enables a set pressure that is only 10% below the maximum allowable working pressure (MAWP) or maximum allowable working vacuum (MAWV) of the tank. After years of development, this typical opening characteristic of a safety relief valve is now also available for the low pressure range.

advanced manufacturing technology

The tank pressure Tank pressure Tank pressure is the pressure within a tank. is maintained up to the set pressure with a tightness that is above The normal standards due to our tate-of-the-art manufacturing technology. This feature is ensured by valve seats made of high quality stainless steel and with individually lapped valve pallets (1), or with an air cushion seal Seal A seal prevents or limits unwanted transfer of product from one container to another. Seal is used as superordinate term for all types of sealing elements. (2), in conjunction with high quality FEP diaphragm Diaphragm A diaphragm is a thin layer of material, which has a large surface area. . The valve pallets are also available with a PTFE seal to prevent them from sticking when sticky substances are used and to enable the use of corrosive fluids. After the overpressure s released, the valve re-seats and provides a tight seal.

Main component - PROTEGO® flame arrester

If the set pressure is exceeded, explosive gas/product vapor/air mixtures are released into the atmosphere. If this mixture ignites, the integrated PROTEGO® flame arrester unit (3) revents flame transmission into the tank. If additional mixture continues to flow and stabilized occurs, the integrated flame arrester prevents flashback Flashback Phenomenon occurring in a flammable mixture of air and gas when the local velocity of the combustible mixture becomes less than the flame velocity, causing the flame to travel back to the point of mixture. as a result of endurance burning. The valve is protected and also fulfils its function under thesesevere conditions. The spring Spring A spring is a spiral of wire which returns to its original shape after it is pressed or pulled. -loaded weather hood Weather hood A weather hood is a cover to protect the internal components of a device from environmental influences. opens as soon as the melting element Melting element The melting element is a component that consists of a housing with a lower and upper part. (4) melts.

Many Individual Certifications

The valve can be used at an operating temperature Operating temperature Temperature reached when the equipment is operating under design conditions. of up to +60°C /140°F and meets he requirements of European tank design standard EN 14015 (Appendix L) and ISO 28300 (API 2000). EU conformity according to the currently valid ATEX directive. Approvals according to other national/international regulations on request.
Product Data and Features

Selección del grupo de explosión

MESGExpl. Gr. (IEC / CEN)Gas Group (NEC)
> 0,90 mmIIAD

Special approvals upon request

Tipo de bridas de conexión

EN 1092-1; Form B1
ASME B16.5 CL 150 R.F.

other types upon request

Modelo y especificación

Any combination of vacuum and pressure levels can be set for the valve
The valve discs are weight-loaded.
Pressure/vacuum relief valve, basic designVD/SV-HRL

Additional special devices available upon request

Settings

Pressure:+3.5 mbar+35 mbar
+1.4 inch W.C.+14 inch W.C.
Vacuum:-2.0 mbar-35 mbar
-0.8 inch W.C.-14 inch W.C.

Higher and lower settings upon request

Selección de materiales para la vivienda

Design AB
HousingSteelStainless Steel
Valve saetsStainless SteelStainless Steel
Gasket
PTFE
PTFE
Weather hoodSteelStainless Steel
Flame arrester unit Flame arrester unit Flame arrester casing with FLAMEFILTER® set. A, BB

Special materials upon request

Combinación de materiales para la unidad apagallamas

Ausführung AB
FLAMEFILTER® cageSteelStainless Steel
FLAMEFILTER®Stainless SteelStainless Steel

Special materials upon request

Selección de materiales para la válvula de presión

Design ABCD
Pressure range [mbar]
[inch W.C.]
+3.5 up to +5.0
+1.4 up to +2.0
>+5.0 up to +14
>+2.0 up to +5.6
>+14 up to +35
>+5.6 up to +14
>+14 up to +35
>+5.6 up to +14
Valve palletAluminiumStainless SteelStainless SteelStainless Steel
SealingFEPFEPMetal to MetalPTFE

Special material as well as higher set pressure upon request

Selección de materiales para la válvula de vacío

Design ABCD
Vacuum range [mbar]
[inch W.C.]
-2.0 up to -3.5
-0.8 up to -1.4
<-3.5 up to -14
<-1.4 up to -5.6
<+14 up to +35
<-5.6 up to -14
<-14 up to -35
<-5.6 up to -14
Valve palletAluminiumStainless SteelStainless SteelStainless Steel
SealingFEPFEPMetal to MetalPTFE

Diagrama de flujo volumétrico

Los diagramas de flujo volumétrico han sido determinados con un banco de pruebas de caudal calibrado y certifi - cado por TÜV. El flujo volumétrico V. en [m³/h] y el CFH se refi eren a las condiciones estándar de referencia de aire según ISO 6358 (20°C, 1bar). La conversión a otras densidades y temperaturas están referidas en el Vol. 1: “Fundamentos Técnicos”.

Detail X

Detail X

Applications