VN-VL-L

Vacuum Relief Valve

Function and Description

Full Lift Technology

The device will start to open as soon as the set pressure is reached and only requires 10% overpressure Overpressure Overpressure refers to an increase in pressure in a system or vessel above the normal operating pressure. to reach full lift. Continuous investments in and a commitment to research and development have allowed PROTEGO® to develop a low pressure valve which has the same opening characteristics as a high pressure safety relief valve. This “full lift type” technology allows the valve to be set at just 10% below the maximum allowable working pressure of the tank and still safely vent the required mass flow.

Advanced manufacturing technology

Due to our highly developed manufacturing technology, the tank pressure Tank pressure Tank pressure is the pressure within a tank. is maintained up to set pressure with a tightness that is far superior to the conventional standard. This feature is achieved by valve seat Valve seat The valve seat is a component on which the valve pallet rests when the valve is closed. made of high quality stainless steel and with precisely lapped valve pallets (1). After the vacuum is released, the valve reseats and provides a tight seal Seal A seal prevents or limits unwanted transfer of product from one container to another. Seal is used as superordinate term for all types of sealing elements. again.
Product Data and Features

Dimensiones

NG300 / 12"300 / 12"300 / 12"
DN 300 /12" 350 / 14" 400 /16"
a 570 / 22.44 570 / 22.44 570 / 22.44
b 215 / 8.46 235 / 9.25 255 / 10.94
c 467 / 18.17 487 / 19.17 507 / 19.96
d 243 / 9.57 268 / 10.55 298 / 11.73
e 500 / 19.69 500 / 19.69 500 / 19.69
f 810 / 31.89 810 / 31.89 810 / 31.89
g 770 / 30.31 770 / 30.31 770 / 30.31

Dimensiones en mm / pulgadas

Dimensions for vacuum relief valve with heating jacket upon request

Selección de materiales para la vivienda

DesignAB CEF
Design Data 2 bar/60°C 2 bar/200°C 2 bar/200°C 16 bar/60°C or 10 bar/200°C 16 bar/60°C or 10 bar/200°C
Housing Aluminium Steel Stainless Steel Steel Stainless Steel
Valve seat Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Protective grating Protective grating Protective grating is used as a barrier against humans, animals, or debris, while still allowing flow of gases Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Sealing PTFE PTFE PTFE PTFE PTFE

Selección de materiales para la válvula de vacío

Design CDEF
vacuum range [mbar]
[inch W.C.]
-2.7 up to -4.6
-1.08 up to -1.84
-4.6 up to -7.9
-1.84 up to 3.16
-7.9 up to -13.5
-3.16 up to -5.4
-13.5 up to -70
-5.4 up to -28
Max. Back pressure Back pressure The back pressure is the sum of built-up back pressure and superimposed back pressure. (up to 60°C) [mbar]
[inch W.C.]
390
156
2700
1080
930
372
6400
2560
Valve pallet Aluminium, thin Aluminium, thick Stainless Steel, thin Stainless Steel, thick
Sealing Metal to Metal Metal to Metal Metal to Metal Metal to Metal

Special materials and higher vacuum settings upon request

Tipo de bridas de conexión

EN 1092-1; Form B1
ASME B16.5 CL 150 R.F.

other types upon request

Modelo y especificación

The valve pallet is weight-loaded.
Vacuum valve in basic designVN-VL-L

Additional special devices available upon request.

Settings

Vacuum:-2.7 mbar-70 mbar

Higher vacuum settings upon request.

Diagrama de flujo volumétrico

Los diagramas de flujo volumétrico han sido determinados con un banco de pruebas de caudal calibrado y certifi - cado por TÜV. El flujo volumétrico V. en [m³/h] y el CFH se refi eren a las condiciones estándar de referencia de aire según ISO 6358 (20°C, 1bar). La conversión a otras densidades y temperaturas están referidas en el Vol. 1: “Fundamentos Técnicos”.

Detail X

Applications