PROTEGO®
Flame Arresters

An industrial pipeline with a large bolted pressure vessel and gauges sits on a waterfront platform, with a cargo ship in the background.

Reliable Explosion Protection

By stopping the propagation of explosions and flashbacks, they protect people, assets, and operations in demanding industrial environments. A Flame Arrester Flame arrester Device fitted to the opening of an enclosure, or to the connecting pipe work of a system of enclosures, and whose intended function is to allow flow but prevent the transmission of a flame. allows the safe passage of gases and vapors while reliably preventing flame transmission. It consists of spirally wound metal bands that create precisely defined flame‑ quenching Quenching Cooling of a fluid by mixing it with another fluid of a lower temperature. gaps. These gaps are engineered to match the ignition and transmission characteristics of explosive vapors, ensuring effective protection under real operating conditions.

Deflagration Flame Arresters

Deflagration Flame Arresters, end-of-line

Detonation Flame Arresters

Please select a Flame Arrester from our range below

Filter products
Device
Type
Place of Installation
Explosion Group
Pressure/Vacuum
Material
Size DN
Design
Heating Jacket
Horizontal / Vertical
Combustion Process
Connection Type

Deflagration Flame Arrester, End-of-Line

BE/AD

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Deflagration Flame Arrester, endurance burning proof, End-of-Line

BE/HK

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Deflagration Flame Arrester, endurance burning proof, End-of-Line

BE/HK-E-IIB

Explosion Group

IIA1
D / IIA
C / IIB1

Deflagration Flame Arrester, endurance burning proof, End-of-Line

BE/HK-E-IIB1

Explosion Group

IIA1
D / IIA
C / IIB1

Deflagration Flame Arrester, endurance burning proof, End-of-Line

BE/HK-E-IIB3

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB

Deflagration Flame Arrester, endurance burning proof, End-of-Line

BE/HR

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Deflagration Flame Arrester, endurance burning proof, End-of-Line

BE/HR-400

Explosion Group

IIA1
D / IIA

Deflagration Flame Arrester, endurance burning proof, End-of-Line

BE/HR-E-IIB

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB

Deflagration Flame Arrester, endurance burning proof, End-of-Line

BE/HR-E-IIB1

Explosion Group

IIA1
D / IIA
C / IIB1

Deflagration Flame Arrester, endurance burning proof, End-of-Line

BE/HR-E-IIB3

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Detonation Flame Arrester

BR/TS-80-IIB-P1,6

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB

Detonation Flame Arrester

BR/TS-80-IIB3

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

In-Line Detonation Flame Arrester

DA-CG

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Eccentric In-Line Detonation Flame Arrester

DA-E

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

In-Line Detonation Flame Arrester

DA-G

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

In-Line Detonation Flame Arrester

DA-SB

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

In-Line Detonation Flame Arrester

DA-SB-EO-P1,1

Explosion Group

EO

In-Line Detonation Flame Arrester

DA-SB-PTFE

Explosion Group

IIA1
D / IIA

In-Line Detonation Flame Arrester

DA-UB

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

In-Line Detonation Flame Arrester

DAZ-S

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

In-Line Detonation Flame Arrester

DR-UN

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

In-Line Detonation Flame Arrester

DR/ES

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

In-Line Detonation Flame Arrester

DR/ES, DN 1/4 - 3/4

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

In-Line Detonation Flame Arrester

DR/ES-PTFE

Explosion Group

IIA1
D / IIA

In-Line Detonation Flame Arrester

DR/ES-V

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

In-Line Detonation Flame Arrester

DR/EU

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

In-Line Detonation Flame Arrester

DR/SBW

Explosion Group

D / IIA
C / IIB3

In-Line Detonation Flame Arrester

DR/SV

Explosion Group

IIA1
D / IIA

Vent Cap, End-of-Line

E/KS

Deflagration Flame Arrester, endurance burning proof, End-of-Line

EB

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB

Deflagration Flame Arrester, endurance burning proof, End-of-Line

EB-Z

Explosion Group

D / IIA

Detonation Flame Arrester,

EF/V-IIB3

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Vent Cap, End-of-Line

EH/0

Vent Cap, End-of-Line

EH/0S

Flame Arrester Unit

EV/VS, EV/VD

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

In-Line Deflagration Flame Arrester

FA-CN-IIA, IIB3

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

In-Line Deflagration Flame Arrester

FA-CN-IIA1

Explosion Group

IIA1

In-Line Deflagration Flame Arrester

FA-CN-IIC

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

In-Line Deflagration Flame Arrester

FA-E

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

In-Line Deflagration Flame Arrester

FA-E-IIA1

Explosion Group

IIA1

In-Line Deflagration Flame Arrester

FA-G

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

In-Line Deflagration Flame Arrester

FA-G-IIA1-P2.2

Explosion Group

IIA1

In-Line Deflagration Flame Arrester

FA-I

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Flame Arrester Unit

FA-I-FC

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

In-Line Deflagration Flame Arrester

FA-I-PTFE

Explosion Group

IIA1
D / IIA

Flame Arrester

FA-I-V, FA-I-P

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Liquid Detonation Flame Arrester

LDA

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Liquid Detonation Flame Arrester

LDA-F

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

In-Line Liquid Detonation Flame Arrester

LDA-W

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

In-Line Liquid Detonation Flame Arrester

LDA-WF(W)

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3

Deflagration Flame Arrester, End-of-Line

LH/AD

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Deflagration Flame Arrester, short time burning-proof, End-of-Line

LH/AD-T

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Deflagration Flame Arrester, endurance burning proof, End-of-Line

LH/EB

Explosion Group

IIA1

Hydraulic Flame Arresters

TS/P, TS/E, TS/W

Explosion Group

IIA1
D / IIA
C / IIB1
C / IIB2
C / IIB3
B / IIB
B / IIC

Highlights of PROTEGO® Flame Arresters

Zero flashback incidents
when sized, located, and maintained per application
Higher uptime & lower losses
via correct tank breathing and explosion protection
Lifecycle confidence
with maintenance-friendly designs and global service
Compliance made simpler
with documented test data and manuals

Working principle of Flame Arresters

 

The FLAMEFILTER® is made of wound metal strips and forms an effective band arrester. This flame-quenching principle is applied in PROTEGO® end-of-line Flame Arresters and in-line Flame Arresters.

When a mixture ignites in a gap, the flame spreads towards the unburned mixture. The volume expansion of the burned mixture pre-compresses the unburned mixture and accelerates the flame propagation.

 

Heat dissipation to the large surface of the gap lowers the temperature below the ignition temperature Ignition temperature Lowest temperature (of a hot surface) at which ignition of a flammable gas or vapor in a mixture with air or air/inert gas occurs under specified test conditions. , thus extinguishing the flame.

The gap width and gap length determine the extinguishing effectiveness of the Flame Arrester.

A narrower and longer gap extinguishes the flame more effectively, while a wider and shorter gap reduces the pressure loss. Experiments can determine the optimum solution between the two conditions.

The PROTEGO® devices are working to our utmost satisfaction. PROTEGO® - who, with their technical expertise, supported in reducing the overall life cycle cost of the Detonation Flame Arresters installed at our plant by installing flame arresters, which are easy to clean and maintenance-friendly. 

Maintenance and Reliability Engineer

DOW UCAR Emulsion Systems Jebel Ali FZE Plant 

Application Examples for PROTEGO® Flame Arresters

  • Refrigerated and Cryogenic Storage

  • Tank Storage

  • Vapor Treatment

  • Chemical and Pharmaceutical Processing Facilities

    Get in Touch

    Contact our engineers for your individual requirements.