ER/V
Emergency pressure relief valve

Features
10% Technology
Extreme Tightness
Optimal Pressure Maintenance
Guided Valve Pallet
Flow Capacity
Used in Explosion Hazardous Areas
Sturdy Housing Design
Secured Housing Cover
API Tanks

Highly Developed Pressure Relief Valve

Full Lift Technology

Advanced Manufacturing Technology
Dimensions
To select the nominal size Nominal size The nominal size is an alphanumeric designation of size for components in a piping system, used for reference purposes, comprising the letters DN followed by a dimensionless integer that is indirectly related to the physical size of the bore or outside diameter of the connections, expessed in millimeters. (DN), use the flow capacity chart on the following page
| DN | 200 / 8" | 250 / 10" | 300 / 12" | 350 / 14" | 400 / 16" | 450 / 18" | 500 / 20" | 600 / 24" | 700 / 28" |
| a | 305 / 12.01 | 375 / 14.76 | 425 / 16.73 | 445 / 17.52 | 495 / 19.49 | 545 / 21.46 | 615 / 24.21 | 715 / 28.15 | 795 / 31.30 |
| b | depending on pressure setting |
Dimensions in mm / inches
Material selection
| Design | A | B | C | D |
| Housing | Steel | Steel | Stainless Steel | Stainless Steel |
| Valve seat Valve seat The valve seat is a component on which the valve pallet rests when the valve is closed. | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Valve pallet | Aluminium* | Steel-Stainless Steel* | Aluminium* | Stainless Steel* |
| Sealing | FPM | FPM | FPM | FPM |
* depending on pressure setting
Special materials upon request
Flange connection type
| EN 1092-1; Form B1 |
| ASME B16.5 CL 150 R.F. |
other types upon request
Design Types and Specifications
The valve pallet is weight-loaded. Higher pressures are achieved with levers (see ER/VH) or with spring Spring A spring is a spiral of wire which returns to its original shape after it is pressed or pulled. -loading (see ER/V-F).Additional special devices available upon request.
Settings
| DN 200 to DN 350 | +5 mbar | +40 mbar |
| +2 inch W.C.J | +16 inch W.C. | |
| DN 400 to DN 700 | +5 mbar | +25 mbar |
| +2 inch W.C.J | +10 inch W.C. |
For higher pressure settings, see types ER/VH and ER/V-F.
Flow Capacity Chart

The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). For conversion to other densities and temperatures refer to Sec. 1: “Technical Fundamentals”.