VN-VU
Vacuum Relief Valve

Features
10% Technology
Extreme Tightness
Optimal Pressure Maintenance
Flow Capacity
Guided Valve Pallet
Used in Explosion Hazardous Areas
Condensate Drainage

Highly Developed Vacuum Relief Valve

Full Lift Technology

Advanced manufacturing technology
Dimensions
| DN | 400 / 16" |
| a | 690 / 27.17 |
| b | 470 / 18.50 |
| c | 750 / 29.53 |
| d | 435 / 17.13 |
| e | 1086 / 42.76 |
Dimensions in mm / inches
Dimensions for vacuum relief valve with heating jacket upon request
Material selection for housing
| Design | A | C | D |
| Housing | Aluminium | Stainless Steel | Low Temperature Carbon Steel |
| Valve seat | Stainless Steel | Stainless Steel | Stainless Steel |
| Protective grating Protective grating Protective grating is used as a barrier against humans, animals, or debris, while still allowing flow of gases | Stainless Steel | Stainless Steel | Stainless Steel |
| Sealing | PTFE | PTFE | PTFE |
Option: Housing with ECTFE- lining Lining Protective plastic lining with a defined minimum/maximum thickness to protect against aggressive mixtures (e.g., acid).
Special materials upon request
Material selection for vacuum valve pallet
| Design | C | D | E | F |
| vacuum range [mbar] [inch W.C.] | -2.6 up to -4.4 -1.04 up to -1.76 | -4.4 up to -7.6 -1.76 up to 3.04 | -7.6 up to -13.2 -3.04 up to -5.28 | -13.2 up to -25 -5.28 up to -10 |
| Max.
Back pressure
Back pressure
The back pressure is the sum of built-up back pressure and superimposed back pressure.
[mbar] [inch W.C.] | 245 98 | 1690 676 | 580 232 | 2000 800 |
| Valve pallet | Aluminium, thin | Aluminium, thick | Stainless Steel, thin | Stainless Steel, thick |
| Sealing | Metal to Metal | Metal to Metal | Metal to Metal | Metal to Metal |
Special materials and higher vacuum settings upon request
Flange connection type
| EN 1092-1; Form B1 |
| ASME B16.5 CL 150 R.F. |
other types upon request
Design Types and Specifications
The valve pallet is weight-loaded.Additional special devices available upon request.
Settings
| Vacuum: | -2.6 mbar | -25 mbar |
| -10 inch W.C. |
Higher vacuum settings upon request.
Flow Capacity Chart

The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). For conversion to other densities and temperatures refer to Sec. 1: “Technical Fundamentals”.


Detail X