D/PA(L)
Pressure or Vacuum Relief Valvewith pipe-away connection

Features
10% Technology
Extreme Tightness
Optimal Pressure Maintenance
Flow Capacity
Used in Explosion Hazardous Areas
Condensate Drainage
API Tanks

Combined Pressure and Vacuum Relief Valve

Full Lift Technology

Advanced manufacturing technology
Dimensions
To select the nominal size Nominal size The nominal size is an alphanumeric designation of size for components in a piping system, used for reference purposes, comprising the letters DN followed by a dimensionless integer that is indirectly related to the physical size of the bore or outside diameter of the connections, expessed in millimeters. (DN), use the flow capacity charts on the following pages
| D/PA | |||||||
| DN 1 | 50 / 2" | 80 / 3" | 100 / 4" | 150 / 6" | 200 / 8" | 250 / 10" | 300 / 12" |
| DN 2 | 50 / 2" | 80 / 3" | 100 / 4" | 150 / 6" | 200 / 8" | 250 / 10" | 300 / 12" |
| a | 165 / 6.50 | 192 / 7.56 | 240 / 9.45 | 350 / 13.78 | 390 / 15.35 | 460 / 18.11 | 460 / 18.11 |
| b | 331 / 13.03 | 402 / 15.83 | 472 / 18.58 | 565 / 22.24 | 682 / 26.85 | 760 / 29.92 | 760 / 29.92 |
| c | 150 / 5.91 | 180 / 7.09 | 200 / 7.87 | 250 / 9.84 | 300 / 11.81 | 305 / 12.01 | 305 / 12.01 |
| d | 180 / 7.09 | 215 / 8.46 | 255 / 10.04 | 300 / 11.81 | 387 / 15.24 | 440 / 17.32 | 467 / 18.39 |
| D/PAL | |||||||
| DN 1 | 50 / 2" | 80 / 3" | 100 / 4" | 150 / 6" | 200 / 8" | 250 / 10" | 300 / 12" |
| DN 2 | 80 / 3" | 100 / 4" | 150 / 6" | 200 / 8" | 250 / 10" | 300 / 12" | 350 / 14" |
| a | 165 / 6.50 | 192 / 7.56 | 240 / 9.45 | 350 / 13.78 | 390 / 15.35 | 460 / 18.11 | 460 / 18.11 |
| b | 342 / 13.46 | 402 / 15.83 | 472 / 18.58 | 565 / 22.24 | 682 / 26.85 | 760 / 29.92 | 770 / 30.31 |
| c | 140 / 5.51 | 143 / 5.63 | 165 / 6.50 | 216 / 8.50 | 267 / 10.51 | 305 / 12.01 | 305 / 12.01 |
| d | 195 / 7.68 | 223 / 8.78 | 280 / 11.02 | 327 / 12.87 | 412 / 16.22 | 467 / 18.39 | 488 / 19.21 |
Dimensions in mm / inches
Dimensions of pressure or vacuum relief valves with heating jacket upon request
Material selection for housing
| Design | C DN50/2”-80/3” | A DN100/4”-300/12” | D/B DN50/2”-300/12” |
| Housing Housing A housing is a solid shell, which surrounds a content, either protecting the content from external influences, or protecting the environment from the content. | Stainless Steel | Steel | Stainless Steel |
| Housing attachment Housing attachment A housing attachment is an assembly, which is used for holding flame arresters or for diverting the flow direction. | Steel | Steel | Stainless Steel |
| Heating jacket(D/PA(L)-H-...) | Stainless Steel/Steel | Stahl | Stainless Steel |
| Valve seat Valve seat The valve seat is a component on which the valve pallet rests when the valve is closed. | Stainless Steel | Stainless Steel | Stainless Steel |
| Gasket | PTFE | PTFE | PTFE |
Option: Housing with ECTFE- lining Lining Protective plastic lining with a defined minimum/maximum thickness to protect against aggressive mixtures (e.g., acid).
Special materials upon request
Material selection for valve pallet
| Design | A | B | C | D | E | F |
| Pressure range [mbar] [inch W.C.] | ±2,0 up to ±3,5 ±0.8 up to ±1.4 | ±3,5 up to ±14 ±1.4 up to ±5.6 | ±14 up to ±35 ±5.6 up to ±14 | ±35 up to± 60 ±14 up to ±24 | ±14 up to ±35 ±5.6 up to ±14 | ±35 up to ±60 ±14 up to ±24 |
| Valve pallet | Aluminium | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Sealing | FEP | FEP | Metal to Metal | Metal to Metal | PTFE | PTFE |
Special materials upon request
For higher set pressure or vacuum, refer to type D/PA(L)-F
Flange connection type
| EN 1092-1; Form B1 |
| ASME B16.5 CL 150 R.F. |
Other types upon request
Design Types and Specifications
The valve pallets are weight-loaded. Higher pressures can be achieved upon request with a special spring Spring A spring is a spiral of wire which returns to its original shape after it is pressed or pulled. -loaded design. Choose the model (L) if the discharge nozzle has a nominal diameter that is greater than the nominal diameter of the tank filler neck.There are four different designs:
Additional special devices available upon request
Settings
| Pressure or vacuum: | ±2.0 mbar | ±60 mbar |
| ±0.8 inch W.C. | ±24 inch W.C. |
Higher or lower settings upon request.For higher set pressure or vacuum refer to type D/PA(L)-F
Flow Capacity Chart


The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). For conversion to other densities and temperatures refer to Sec. 1: “Technical Fundamentals”.


Detail X

Detail X

Tankanschluss bei Überdruckfunktion

Tankanschluss bei Unterdruckfunktion