Features
Venting and Breathing of Floating Roof Tanks
Low Position of the Floating Roof
Different Heights
Conversion
Adjustment Through an Adjustment Option
Not Flame Transmission Proof

Automatic Venting Valves for Floating Roof Tanks

Design of Valves
Dimensions for Different Floating Roof Heights
Conversion of Floating Roof Supports and Extension of the Plunger
Maßtabelle für AL-DK und AL-DK-4
| AL-DK | AL-DK-4 | |||||||
| DN1 | 200 / 8" | 200 / 8" | 200 / 8" | 200 / 8" | 250 / 10" | 250 / 10" | 200 / 8" | 200 / 8" |
| DN2 | 80 /3" | 100 /4" | 150 / 6" | 200 / 8" | 150 / 6" | 200 / 8" | 100 /4" | 200 / 8" |
| a | 350 / 13.78 | 350 / 13.78 | 350 / 13.78 | 350 / 13.78 | 350 / 13.78 | 350 / 13.78 | 350 / 13.78 | 350 / 13.78 |
| b | 465 / 18.31 | 465 / 18.31 | 465 / 18.31 | 515 / 20.28 | 465 / 18.31 | 515 / 20.28 | 465 / 18.31 | 650 / 25.59 |
| c | 870 / 34.25 | 870 / 34.25 | 870 / 34.25 | 870 / 34.25 | 870 / 34.25 | 870 / 34.25 | 870 / 34.25 | 870 / 34.25 |
| d | 450 / 17.72 | 450 / 17.72 | 450 / 17.72 | 450 / 17.72 | 450 / 17.72 | 450 / 17.72 | 450 / 17.72 | 600 / 23.62 |
| e | 345 / 13.58 | 360 / 14.17 | 385 / 15.16 | 415 / 16.34 | 385 / 15.16 | 415 / 16.34 | 415 / 16.34 | 415 / 16.34 |
| f | 460 / 18.11 | 445 / 17.52 | 285 / 11.22 | 370 / 14.57 | 285 / 11.22 | 367 / 14.45 | 445 / 17.52 | 370 / 14.57 |
| x | 658 / 25.91 | 920 / 36.22 | ||||||
Dimensions in mm / inches
Material
| Housing | Steel |
| Valve guide | Stainless Steel |
| Gasket | FPM |
Special materials upon request
Flange connection type
| EN 1092-1; Form B1 | andere Anschlüsse auf Anfrage |
| ASME B16.5 CL 150 R.F. |
Other types upon request
Flow Capacity Chart

The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). For conversion to other densities and temperatures refer to Sec. 1: “Technical Fundamentals”.
Application Examples for PROTEGO® AL-DK
Lift-actuated vent valves of type PROTEGO® AL-DK can be combined with vent caps type EB which are deflagration Deflagration Explosion propagating at subsonic velocity. proof and resistant against endurance burning Endurance burning Stabilized burning for an unlimited time. . This ensures flame transmission proof ventilation.

If resistance against endurance burning is not required the valves can alternatively be combined with PROTEGO® deflagration proof devices type PROTEGO® LH/AD. The applicable data sheets are available in volume 2 “Deflagration Flame Arresters Flame arrester Device fitted to the opening of an enclosure, or to the connecting pipe work of a system of enclosures, and whose intended function is to allow flow but prevent the transmission of a flame. , end-of-line and Vent Caps”.




PROTEGO®
Representative